Difference Between AFM and STM
AFM vs STM
AFM refers to Atomic Force Microscope and STM refers to Scanning Tunneling Microscope. The development of these two microscopes is considered a revolution in the atomic and molecular fields.
When talking of AFM, it captures precise images by moving a nanometer sized tip across the surface of the image. The STM captures images using quantum tunneling.
Of the two microscopes, the Scanning Tunneling Microscope was the first to be developed.
Unlike the STM, the probe makes a direct contact with the surface or calculates the incipient chemical bonding in AFM. The STM images indirectly by calculating the quantum degree tunneling between he probe and sample.
Another difference that can be seen is that the tip in AFM touches the surface gently touches the surface whereas in STM, the tip is kept at a short distance from the surface.
Unlike the STM, the AFM does not measure the tunneling current but only measures the small force between the surface and the tip.
It has also been seen that the AFM resolution is better than the STM. This is why AFM is widely used in nano-technology. When talking of the dependence between force and distance, the AFM is more complex than the STM.
When Scanning Tunneling Microscope is normally applicable to conductors, the Atomic Force Microscope is applicable to both conductors and insulators. The AFM suits well with liquid and gas environments whereas STM operates only in high vacuum.
When compared to STM, the AFM gives a more topographic contrast direct height measurement and better surface features.
Summary
1. AFM captures precise images by moving a nanometer sized tip across the surface of the image. The STM captures images using quantum tunneling.
2. The probe makes a direct contact with the surface or calculates the incipient chemical bonding in AFM. The STM images indirectly by calculating the quantum degree tunneling between he probe and sample.
3. The tip in AFM touches the surface gently touches the surface whereas in STM, the tip is kept at a short distance from the surface.
4. AFM resolution is better than the STM. This is why AFM is widely used in nano-technology.
5. When Scanning Tunneling Microscope is normally applicable to conductors, the Atomic Force Microscope is applicable to both conductors and insulators.
6. The AFM suits well with liquid and gas environments whereas STM operates only in high vacuum.
7. Of the two microscopes, the Scanning Tunneling Microscope was the first to be developed.
- Difference Between CNBC and Fox Business - October 3, 2011
- Difference Between Distilled Water and Boiled Water - September 30, 2011
- Difference Between McDonalds and Burger King - September 30, 2011
Search DifferenceBetween.net :
Email This Post : If you like this article or our site. Please spread the word. Share it with your friends/family.
It isn’t true that STM only works under ultra high vacuum (UHV). Much interesting work on self-assembly has been done at the liquid-solid interface.
information about STM and new of AFM
Thank you
Good technical Information, thank you
STM offers higher resolution than AFM
Are you sure?
What about resolution?
I have just red on anothser website ” RESOLUTION:
STM gives better resolution than AFM because of the exponential dependence of the tunneling current on distance.
The force-distance dependence in AFM is much more complex when characteristics such as tip shape and contact force are considered. ” -> http://www.biotecharticles.com/Biotech-Research-Article/Difference-Between-Scanning-Tunneling-and-Atomic-Force-Microscopes-429.html
I agreed with two comments above.
Very helpful, thank you